Application

Ball valve is isolating valve designed to fully open or close the service fluid flow. It is not designed to be used for throttling or regulating purposes. For temperatures up to +500 °C (for temperatures above +400 °C for non-oxidizing fluids only).

Suitable for water, steam, gas, oil, heat transfer fluids and other liquids and gases without mechanical impurities.

Approved for fluids in groups 1 (hazardous) and 2 according to 2014/68/EU.

Production range

  • DN 10 – DN 100, PN 16 – PN 160
  • NPS ½″ – NPS 4″, Class 150 – Class 900

Characteristics

  • floating ball,
  • full bore,
  • anti-static design,
  • stem secured against release (anti-blow-out).

Operation

  • hand lever,
  • hand wheel with worm gear,
  • pneumatic actuator,
  • electric actuator.

Connection to piping

  • internal thread (KM 9101.X-HT) – G (BSPP), NPT, R (BSPT), Rp
  • weld end (KM 9103.X-HT) – butt or socket
  • flanged (KM 9108.X-HT) – EN, API, GOST

Compliance with standards

  • European standards:
    • EN 1983, EN 12516–1, EN 1092–1, EN 17292,
    • EN 558–1 series 1 or not standardised, EN 12982 series 68,
    • DIN 3357 or not standardised,
    • EN 228–1,
    • EN 13463–1 (ATEX) – II 1 GD Ex IIC TX, I M1.
  • American standards:
    • API 608, ANSI B 16.5, ANSI B16.25, ANSI B 1.20.1,
    • ANSI B 16.10 or not standardised,
  • international standards:
    • EN ISO 5211,

Testing

  • EN 12266–1, EN 12266–1, leakage rate A – zero leakage,
  • API 598, or acc. to API 6D – zero leakage.

Materials

  • standard: S355J2, A350 LF2, 1.4541, 1.4571, 1.5415 (16Mo3),
  • upon request: P265GH, 1.4306, 1.4462, 1.7335 , and other.

Optional accessories, adjustments and services

  • different face-to-face dimensions or end combinations,
  • adaptation of face form (Groove, Tongue, Spigot, Recess, O-ring groove, RTJ),
  • connection for actuator according to ISO 5211,
  • fire-safe design – fire resistance in accordance with EN ISO 10497 (API 607),
  • heating jacket – for keeping the fluid liquid,
  • lockable handle with a padlock,
  • extended stem – e.g. for the reason of insulation of the valve and pipeline,
  • design according to TA-Luft or EN 15848–1,
  • limit switches,
  • documentation according to EN 10204 3.2,
  • special adjustments according to customer requests,
  • design according to standard NACE MR 0175 or ISO 15156.

Pressure-temperature graph

Type designation


© KE-ARM, s.r.o.